Product name | pH meter with automatic calibration function |
---|---|
Type | AH-151-CH (dip type), -CF (flow-through type), -FK (water sampling type) |
Measuring method | Glass electrode method |
Measuring range | pH: 0 to 14 Resolution: 0.01 pH |
Display unit | Touch panel (TFT color LCD) |
Repeatability | pH: within ±0.02 pH, Temperature: ±0.3°C (Equivalent input) |
Linearity | pH: within ±0.03 pH, Temperature: ±0.3°C (Equivalent input) |
Transmission output | Number of output points: 2, Output form: 4 to 20 mA DC input/output insulation type, Load resistance: Maximum 900 Ω |
Contact output | Number of output points: 9 and 1 (abnormality alarm), Output form: No-voltage contact output, |
Cleaning interval | 0.1 to 168.0 hours, Month, day and time of start of next cleaning can be set, Cleaning time: Approx. 2 minutes (default setting) |
Calibration interval | 1 to 999 hours, Month, day and time of start of next calibration can be set, Calibration time: Approx. 5 minutes (default setting when pH electrode is new) |
Contact input | Number of input points: 3, Contact: No-voltage “a” contact for open collector, Contact function: External commands for cleaning performance (automatic cleaning start, automatic calibration start, stand-by commands) |
Communication capability | RS-485 two-wire system, Input/output insulation type (not insulated from transmission output) |
Combined electrode | Glass electrode 6108 |
Calibration method | Automatic calibration (lift-up type calibration with standard solution spray) or manual calibration |
Cleaning method | Lift-up type cleaning with cleaning solution |
Self-check | Calibration error, Electrode check, System error |
Sample conditions | Pressure: Atmospheric pressure, Temperature: -5 to 80°C, Flow velocity: 2 m/sec or less, Flow rate: 10 L/min or less (only for flow-through type), Conductivity: 10 mS/m (100 μS/cm) or more |
pH standard solution | Two solutions (pH7 and pH4 or pH9), Consumption: Approx. 30 to 40 mL/min (max. 200 mL/calibration), Capacity: PE tank 3 L (calibration approx. 15 to 50 times possible) |
Cleaning chemical | HCI: less than 5 to 10%, Consumption: Approx. 50 mL/cleaning (approx. 75,100 mL/cleaning, adjustable) Capacity: PE tank 20 L (cleaning approx. 300 times possible, using 50 mL each time) |
Water supply | Water quality: Tap water equivalent (industrial water possible), Pressure: 0.2 to 0.75 MPa, Consumption: 10 to 20 L/cleaning, calibration one time (in case of default setting for cleaning time) |
Air supply | Air quality: Instrument air, Pressure: 0.3 to 0.7 MPa, Consumption: 10 to 15 L/min |
Inlet | Supply water: Rc1/2, Air: Rc1/4 |
Cable gland | 8 cable glands for φ7 to φ12 (without cable gland, φ21.5 hole) |
Operating temperature range | 0 to 50°C (no condensation) |
Power supply | Voltage range: 100 to 240V AC ±10%, 50/60 Hz, Power consumption: 100V AC, approx. 20 W during steady state and approx. 35 W during auto-calibration |
Structure | Outdoor setting type: JIS C0920 explosion/splash-proof type (IP54 equivalent), Material of control unit case: SPCC (coated with melamine-based epoxy resin), Metal fittings: SUS304, Stand: SUS304 |
Mass | Operation unit & pole stand: Approx. 60 kg, Metal fittings: Approx. 3 kg, Lifting unit (dip type): Approx. 1.5 kg (except for dip-type holder) |
Note: Although a surge arrester (discharge starting voltage: 400V) is installed for transmission output, contact input and communications, please install an appropriate surge absorber on the connecting line, according to the surrounding environment, equipment installation condition, peripheral equipment, etc.