Name | Process Laser Gas Analyzer |
Model | PLGA-1000 |
Measurement principle | NDIR: Non Dispersive Infrared |
Light source | QCL: Quantum Cascade Laser |
Laser class | Class 1(IEC 60825-1:2014) |
[ For C2H2 Converter Inlet ]
Components*¹ | Acetylene (C2H2), Carbon monoxide (CO) |
Range | C2H2 : 0 - 10000 ppm, CO: 0 - 2000 ppm |
Linearity | ±1.0 % full scale |
Response time | Td + T90 : 3 seconds at 1.6L / min |
Zero drift | ±2.0 % full scale per 1 month |
Span drift | ±2.0 % full scale per 1 month |
[ For C2H2 Converter Outlet ]
Components*¹ | Acetylene (C2H2), Carbon monoxide (CO) |
Range | C2H2 : 0 - 10 ppm, CO: 0 - 10 ppm |
Linearity | ±1.0 % full scale |
Response time | Td + T90 : 7seconds at 1.6L / min |
Zero drift | ±3 % full scale per 1 month |
Span drift | ±3 % full scale per 1 month |
[ For C2 Splitter Inlet ]
Components*¹ | Methane (CH4), Ethane (C2H6), Acetylene (C2H2), Carbon Dioxide (CO2) |
Range | CH4 : 0 - 2000 ppm or 0 - 5 vol% C2H6 : 0 - 50 vol% C2H2 : 0 - 50 ppm CO2 : 0 - 200 ppm |
Linearity | ±1.0 % full scale |
Response time | Td + T90 : 3 sec at 1.6L / min |
Zero drift | ±2.0 % full scale per 1 month |
Span drift | ±2.0 % full scale per 1 month |
[ Common ]
Repeatability | ±1.0 % full scale |
Data update cycle | 1 sec |
Calibration interval | 1 month |
Ambient temperature | -10˚C to 50˚C or -10˚C to 45˚C (no direct sun rays, including case temperature influences due to radiant heat and heat conduction) *The flow rate of the protective gas differs depending on the specification of the ambient temperature |
Hazardous area classification | US, Canada: Class I, Division 2, Groups A, B, C, D T4 US: Class I, Zone 2, AEx pzc IIC T4 Gc IECEx, Canada: Ex pzc IIC T4 Gc ATEX, UKCA: II3G Ex pzc IIC T4 Gc |
Protection class | IP66、NEMA4X |
Wetted materials | SS316, SS304, BaF2, FKM, PTFE, Au, Ni |
Gas connector size | 1/4"NPT, 1/2"NPT (Option: N2 generator) |
Pressure error alarm output | Three channels (Main enclosure, Optical unit, Cell) DC 5 V to 24 V, 1 A at each terminal |
Communication function | Modbus®/ TCP |
Analog output | Four channels (Gas concentration) 4 mA to 20 mA Max. load: 550 Ω |
Contact output | Three channels (Calibration / Main alarm / Measurement) Relay contact output (isolated output) DC 5 V to 24 V, 1 A at each terminal |
Digital output | One channel (For signal barrier power control relay) DC 24 V, 100 mA |
Dimension | 664 mm (W) x 270 mm (D) x 704 mm (H) *Protrusions included |
Weight | Standard 46 kg, Max. 50 kg *Depends on product specifications |
Power supply | AC 100 V to 120 V, 50 Hz/60 Hz or AC 200 V to 240 V, 50 Hz/60 Hz |
Power consumption | Max. 250 VA |
*¹ Please contact us for other components and range.