Click here to view M116’s Hyperspectral configuration: H116
8-channel Spectrometer Specifications* | |
---|---|
Spectral Coverage | 185 - 1050 nm (extension to low UV with N2 purge) Tunable at factory between these ranges: 185-920 nm and 280-1050 nm |
Spectrometer Input | 8 channel, φ200 μm core fibers with φ220 μm clad, separated by a φ220 μm dead fiber |
Spectral Resolution | 1.25 nm typical (22 μm slit width) and up, depending on the slit size |
Spectral Dispersion | 34.6 nm/mm; 0.38 nm/pixel |
Crosstalk (Adjacent Channel)* | < 0.1% (measured @ 600 nm) |
Crosstalk (Non-adjacent Channel)* | < 0.1% (measured @ 600 nm) |
Focal Length | 116 mm |
F/# | F/2.3 |
Smile and Keystone | 1.5 pixel (typical) |
Stray Light*** | < 0.1% (typical) |
Wavelength Accuracy | 0.1 nm (using 8 channel wavelength calibration) |
Software | LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration) |
16-channel and 32-channel Spectrometer Specifications | |
---|---|
Spectral Coverage | 185 - 1050 nm (configurable based on customer’s need) |
Spectrometer Input | 16 channel, φ100 μm core fibers with φ110 μm clad 32 channel, φ70 μm core fibers with φ77 μm clad |
Spectral Resolution | 1 nm and up depending on fiber core size |
Spectral Dispersion | 34.6 nm/mm; 0.38 nm/pixel |
Focal Length | 116 mm |
F/# | F/2.3 |
Smile and Keystone | 1.5 pixel (typical) |
Stray Light | < 0.1% (typical) |
Wavelength Accuracy | 0.1 nm (using 32 channel wavelength calibration) |
Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics | ||
---|---|---|
Detector Model | sCMOS BI sensor with electronic rolling shutter (all the parameters are specified at normal room temperature of 25º C unless otherwise noted) | |
Sensor Format**** | 2048 x 512 | |
CMOS Pixel Size | 11 μm x 11 μm | |
CMOS Height | 5.6 mm | |
CMOS QE | The peak QE is 77% at 250 nm and 95% at 560 nm | |
Thermoelectric Cooling | Uncooled | |
Frame Rate | 94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor | |
Full Well | 80 ke¯ typical (HDR mode) | |
Readout Noise | 1.6 e¯ typical, 2.0 e¯ maximum | |
Digitization | 16-bit (HDR mode), 12-bit (High Sensitivity mode) | |
Dynamic Range | 93.9 dB typical in HDR mode | |
Non-linearity (measured on each system) | 1.8% (maximum) in HDR mode | <0.9% (maximum) in High Sensitivity mode |
Communication | USB 3 | |
Environmental Conditions | Operating temperature 15°C to 40°C ambient; Relative humidity <70% (non-condensing); Storage temperature -25°C to 45°C | |
Power requirements AC/DC power supply (provided) | 90-264 VAC, 47–63 Hz |
* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.
** Crosstalk (to adjacent channels): the % of signal leaking to the adjacent channels while one channel is on and others are off.
*** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.
**** See sensor manufacturer’s Blemish / Defect information
Mechanical Drawings
You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733